1. MODBUS TEMP CONTROL HEAT ONLY SSR

901 MODEL / HEATSINK
200 AMP SSR LOAD CURRENT @ 40°C
A-100 80 Amp
A-190 Heat Sink without Fan 44 A x 3 = 132 Amp
A-190 Heat Sink with Fan 52 A x 3 = 156 Amp

UNI 901 MOD TC ONF 60 200 485 CU2 CT60 JK HO


Temp Controller with Normal PID+Fuzzy Control+

2 Degree of freedom+Adaptive Control (Heat Only)

Interact to HMI or PLC on Modbus RTU 485 protocol

Select J or K TC (RTD optional), CJC in the SSR

247 nos. HEX address selection on SSR by 2 switch

Baud rate: 9600/19200/57600/115200 bps by switch

Parity On/Off, Even/Odd, Stop bit 1/2 by switch

Ext. CT for Current & Load failure indication

O/p 24-600VAC/47-63Hz/ 200 Amp/ Zero cross over

All input isolated, RS485 as per IEC 61000 STD.


2. MODBUS TEMP CONTROL HEAT & COOL SSR

901 MODEL / HEATSINK
90 AMP SSR LOAD CURRENT @ 40°C
B-48 36 Amp
B-72 60 Amp
A-100 65 Amp
A-190 Heat Sink without Fan 36 A x 3 = 108 Amp
A-190 Heat Sink with Fan 40 A x 3 = 120 Amp

UNI 901 MOD TC ONF 60 90 485 CU2 CT60 JK HC


Temp Controller with Normal PID+Fuzzy Control+

2 Degree of freedom+Adaptive Control (Heat+Cool)

Interact to HMI or PLC on Modbus RTU 485 protocol

Select J or K TC (RTD optional), CJC in the SSR

247 nos. HEX address selection on SSR by 2 switch

Baud rate: 9600/19200/57600/115200 bps by switch

Parity On/Off, Even/Odd, Stop bit 1/2 by switch

Ext. CT for Current & Load failure indication

O/p 24-600VAC/47-63Hz/ 90 Amp/ Zero cross over

All input isolated, RS485 as per IEC 61000 STD.


 
 